*** Settings ***
|
|
Test Setup Create Machine
|
|
|
|
*** Keywords ***
|
|
Create Machine
|
|
Execute Command include @platforms/cpus/egis_et171.repl
|
|
Create Log Tester 0
|
|
|
|
*** Test Cases ***
|
|
Reading From Trigger Type Array Should Not Be Unhandled
|
|
Execute Command plic ReadDoubleWord 0x1080
|
|
Should Not Be In Log plic: Unhandled read from offset 0x1080
|
|
|
|
Trigger Type Should Be Level
|
|
${actual_trigger_types}= Execute Command plic ReadDoubleWord 0x1080
|
|
${expected_trigger_types}= Set Variable 0
|
|
Should Be Equal As Integers ${actual_trigger_types} ${expected_trigger_types} Interrupt trigger types should be set to Level-triggered
|
|
|
|
First Bit Of First Type Register Should Always Be Zero
|
|
${register_contents}= Execute Command plic ReadDoubleWord 0x1080
|
|
${first_bit}= Evaluate ${register_contents.strip()} & 0b1
|
|
${hardwired_zero}= Set Variable 0
|
|
# Zero is not a valid interrupt source number so bit 0 of the first register must be hardwired to 0.
|
|
Should Be Equal As Integers ${first_bit} ${hardwired_zero} First bit of first register should be zero
|