*** Settings *** Test Setup Create Machine *** Keywords *** Create Machine Execute Command include @platforms/cpus/egis_et171.repl Create Log Tester 0 *** Test Cases *** Reading From Trigger Type Array Should Not Be Unhandled Execute Command plic ReadDoubleWord 0x1080 Should Not Be In Log plic: Unhandled read from offset 0x1080 Trigger Type Should Be Level ${actual_trigger_types}= Execute Command plic ReadDoubleWord 0x1080 ${expected_trigger_types}= Set Variable 0 Should Be Equal As Integers ${actual_trigger_types} ${expected_trigger_types} Interrupt trigger types should be set to Level-triggered First Bit Of First Type Register Should Always Be Zero ${register_contents}= Execute Command plic ReadDoubleWord 0x1080 ${first_bit}= Evaluate ${register_contents.strip()} & 0b1 ${hardwired_zero}= Set Variable 0 # Zero is not a valid interrupt source number so bit 0 of the first register must be hardwired to 0. Should Be Equal As Integers ${first_bit} ${hardwired_zero} First bit of first register should be zero